Flue Sizing

 

Flue Size Selection Guide

The chimney size should be as recommended by the appliancemanufacturer. Where there is a requirement for a flue diameter smallerthan the appliance spigot, then the operational requirements of theappliance and the configuration of the flue must satisfy the fluesizing requirements of DIN4705. For more information contact the installer helpline. The information and sizes below are provided as anominal guide only.

Flue sizing for appliances, particularly commercial/industrial applications, will vary depending on siting details and appliance manufacturer’s instructions and design criteria.These will override the sizing guide and reference must be made to appliance manufacture. For Inglenook and non-standard openings, the diameter of the flue must be at least 15% of the cross sectional areaof the fireplace opening.

Use the wizard to determine the required size,
or if you prefer you can refer to the table below.

Flue Sizing Wizard
 
80
mm
100
mm
130
mm
150
mm
180 to
400mm
Gas - Atmospheric Boiler
 
Input up to 25kW
Input 25kW-40kW
 
Input 40kW-60kW
Gas - Commercial/Industrial Boilers
Input up to 50kW to 70kW
•2
Gas Fires
'Radiant' - BS7977-1 2002
'Inset' - BS7977-1 2002
•1
•1
'Backboiler' - BS7977-2 2003
Gas Water Heaters
Input up to 25kW
Input 25kW to 55kW
Input 55kW to 60kW
Input over 60kW
•2
Gas Warm Air Units
Input up to 18kW
Input 18kW to 35kW
Input 35kW to 60kW
Input over 60kW
•2
Gas Stove/Cooker
•2
•2
•2
Kerosene (28 sec Class C2) Heating Boiler
Output up to 25kW
Input 25kW to 45kW
Input 45kW to 70kW
Kerosene Stove/Cooker
•3
•3
•3
Kerosene Water Heater
Input up to 41kW
Kerosene Visual Effect Stove
Input up to 17kW
•3
•3

Use the wizard to determine the required size,
or if you prefer you can refer to the table below.

Flue Sizing Wizard
 
100mm
130mm
150mm
180mm
200mm
230mm 250 - 400mm
Gas Boiler - Forced Draught
 
Input up to 25kW
Input 25kW-45kW
 
Input 45kW-50kW
Input 50kW-75kW
 
Input 75kW-100kW
Input over 100kW
 
•2
Gas Fires
'Inset' to BS7977-1 2002
•1
'Decorative' to BSEN 509:2000
Gas Oil (35 sec Class D) Heating Boiler
Output up to 25kW
Input 25kW to 45kW
Input 45kW to 70kW
Input 70kW to 100kW
Output over 100kW
•3
•3
•3
Solid Fuel Heating Boiler
Output up to 20kW
•S
•SC
Output 20kW to 30kW
•S
•SC
•SC
Output 30kW to 60kW
•SC
•SC
•SC
Open Fires (Standard opening) 500mm x 550mm
•200
mm
'Avant Garde' Feature Open Fires
•4
Room Heaters
•S
Wood burning Stoves/Cookers. Use only seasoned wood which has been stored 1/2 years in dry conditions.
•200
mm
Inglenook or nonstandard opening. The Cross sectional area of the chimney liner must be a minimum of 15% of the total cross sectional area of the fireplace opening.
•230
mm

Key to annotation on tables

1 Subject to appliance manufacturer's testing criteria.
2. Subject to manufacturer's input rating and chimney height.
3. Subject to manufacturer's output rating and chimney height.
4. Min 300mm depending on opening, chimney size and height.
S Smokeless fuel only.
SC Smokeless fuel or coal.

This information and sizes are provided as a nominal guide only. Flue sizing for appliances, particularly commercial/industrial applications will vary depending on siting details and appliance manufacturer's instructions and design criteria. These will override the sizing guide below and reference must be made to appliance manufacturer.